• Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch
  • Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch
  • Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch
  • Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch
  • Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch
  • Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Customized: Customized
Certification: ISO9001, CE
Display Type: Mechanical Dial Knob
Name: Hydraulic Capillary Thermostat
Length of Capillary: 300mm~3000mm,Customized
Material of Terminal: Brass
Samples:
US$ 2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
JY-CT-D
Center of Mounting Hole
28mm
Min. Capillary Bend Radius
5mm
Temperature′s Rate of Change
1°c/Min
Life
100000 Cycles
Temperature
Customized
Certificate
UL, CE, CQC, RoHS
Application
Water Heater, Water Boiler, Electric Oven,
Temperature Range
-35c~ +320c
Temperature Differential
5% of Action Temperature
Material of Capillary and Sensing Bulb
Stainless Steel and Copper Optional
Diameter of Sensing Bulb
3mm, 4mm, 5mm, 6mm
Electric Rating
16(3)a 250VAC~10(1.8)a 400V
Transport Package
Carton and Wooden Box
Specification
Standard
Trademark
JAYE
Origin
China
HS Code
9032899090
Production Capacity
80000PCS/Month

Product Description

Type D Hydraulic Capillary Thermostat

When the temperature of the controlled object changes, the substance (generally liquid) in the temperature sensing part of the temperature controller will generate the corresponding physical phenomenon (volume change) of thermal expansion and cold contraction, and the capsule connected with the temperature sensing part will generate expansion or contraction. Based on the principle of lever, the on-off action of switch is driven to achieve the purpose of constant temperature.

The liquid expansion temperature controller has the characteristics of accurate temperature control, stable and reliable, small temperature difference between start and stop, wide range of temperature control and adjustment, and large overload current.

The thermostat shown in the picture is a kind of universal Capillary Termostat applied in a number of electrical appliances. According to the customized specifications, it could be made to control temperature from -35 deg C to +350 deg C. More technical information of this Capillary Termostat will be shown in the table below.
Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Features: 

1.Strictly comply with UL, CE, CQC, RoHS

2.Available in a wide temperature range and differential

3.Temperature adjustable through adjusting shaft

4.Auto-reset, manual-reset, and fixed temperature design available

5.Snap-Action electric switch

6.Little magnetic interference

7.Long life usage

8.Accessories, such as knob, bezel, capillary gland kit etc. available

9."D" shaped adjusting shafts with different lengths are available according to a variety of electrical appliances

E Type Capillary Termostat

Temperature Range of Capillary Termostat -35°C~ +320°C
General Temperature Range +0°C~+40°C
+30°C~+85°C
+30°C~+90°C
+30°C~+110°C
+30°C~+185°C
+50°C~+300°C
+50°C~+320°C
Temperature Differential 5% of Action Temperature
Length of Capillary 300mm~3000mm optional
Material of Capillary and Sensing Bulb Stainless Steel and Copper optional
Diameter of Sensing Bulb 3mm,4mm,5mm,6mm
Electric Rating 16(3)A 250VAC~10(1.8)A 400V
Wiring Diagram Single PoleSingle Throw (SPST)
Single Pole Double Throw (SPDT)
Material of Terminal Brass
Mounting Hole 2-M4
Center of Mounting Hole 28mm
Min. Capillary Bend Radius 5mm
Temperature's Rate of Change 1°C/min
Life 100000 cycles

Precautions for use:
1. When the liquid expansion capillary temperature controller leaves the factory, the regulating shaft is at the high temperature point;

2. When installing the liquid expansion temperature controller, the temperature sensing package shall be as close to the surface of the controlled temperature object as possible, or the whole temperature sensing package and the temperature measuring medium shall have good heat conduction, which can reduce the temperature error and achieve the goal of accurate temperature control. During installation, the temperature sensing package shall not be deformed to avoid affecting its performance;

3. Corrosive liquid or conductive medium enters into the liquid expansion thermostat or pollutes the thermostat surface, so as not to affect the electrical insulation performance and product function;

4. When installing the hydraulic expansion thermostat, do not press the main body with the fastening screw. M4 * 5 or M4 * 6 is the appropriate fastening screw to avoid the main body deformation and the action temperature drift;

5. Capillary tube and temperature sensing bag are vulnerable parts, which shall not be bruised, flattened or broken. The main body and the junction between the temperature sensing cylinder and capillary tube shall not be twisted within 40mm. The bending radius of capillary tube shall be greater than 5mm. The capillary tube is hollow wire. Do not bend hard or at right angles to avoid blocking the flow of liquid inside.


Related Products:
Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch
Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Workshop:
Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Certificate:
Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Hot Sale Type D Hydraulic Capillary Thermostat Temperature Protector Switch

FAQ
 
(1). Q: Can you give me a discount price?
A: It is depending on the quantity. The larger the quantity is, the more discount you can enjoy.
(2). Q: How can I get a sample?
A: Normally For most our products can be sent free of sample charge if the quantity is small and customers only need to bear the shipping charge, or you can provide your DHL,FEDEX,EMS,UPS courier account number to us. If the quantity is big, we need to charge a sample fee.
(3). Q: Why does your price a bit higher than other Chinese suppliers?
A: We are focusing on manufacuturing high quality performance products in order to establish a long term and friendly cooperation with all customers.
Our price maybe not the lowest, but our cost performance is the highest.

(4). Q: How can you guarantee the quality of mass production keep the same with the sample sent to me before?
A: Our warehouse staff will leave another same sample with your company name marked in our company before sending the samples to you to ensure the same production as the samples.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now